FURNACES FOR CERAMIC FIRING


 

ELECTRIC HEAT TREATMENT FURNACES

FOR CERAMIC FIRING

 

Universal solution for any ceramic firing and glass melting processes.

 Furnaces are made out of high quality, light, fireproof  insulation materials, that ensures low power consumption, as well as low temperature of external surface.

 

KVU 110/1200  

 

Model

Теmp. max

Inner dimensions, mm

Outer dimensions, mm

Power

Connection

Voltage

 

oC

w

d

H

W + automation

D

H

kW

V

A

KVK 50/1300

1300

350

350

500 (450)

680+160

780

980

3,6

230 1/N

13

KVK 110/1300

1300

480

480

560

850+160

930

1100

9,0

380 3/N

16

KVK 160/1300

1300

900

480

560

1230+160

930

1200

12,0

380 3/N

16

 

 

Description:

§  Furnaces are simple and easy to use!

§ The opening mechanism of the lid is based in gas pressure springs, thus ensuring easy opening of the lid;

 

Heating elements and thermocouple

§ Heating from 4sides (heating elements are placed in all side walls);

§ Heating elements are placed in grooves;

§  Heating elements are made of high quality materials. Most optimal wire size and lenght ensures long service life;

§  The arrangement of heating elements ensures optimal heat distribution in the chamber;

 

Insulation materials

§  Working camera made from lightweight refractory bricks;

§  Furnace insulation is made from ThermalCeramics® high quality lightweight refractory materials;

§ Very low temperature of external construction (+/- 70o C);

 

Another standartd features

§ Casting made of steel tubes and sheets;

§ Surface of the furnace is treated with long life powder-spray coating.

§ Heating elements, that are embedded in floor, are protected by a plate or refractory concrete

§ Door safety switch that shuts down power when door is opened.

 

KOMPLEKTĀCIĀ PAPILDUS IEKĻAUTS:

 

Perfectly suitable for processes, where are need for several segments and cotrolled cooling!

 

§ Possible to store up to 6 programs;

 

§ Error and breakdown mesessages are saved;

 

§ Operation is based on contactors;

 

§ Instruction manual in english!

 

§ Heat treatment curve can be set up by following steps:

 

         § Delayed start ( up to 9h 59min);

 

        § Heating (controlled from 1 to 999°C/h or full power “SKIP”) untill the               intermediate temperature;

 

         § Heating (controlled from 1 to 999°C/h or full power  “SKIP”) untill the             end temperature;

 

         § Retention time (up to 9h 59min);

 

        § Cooling down (cotrolled from 1 to 999°C/h or uncontrolled “SKIP”)                till 150°C

 

 

 

 

 

For more detailed information, please, contact us!

 

 

 

© Keramserviss 1999 Home / About Keramserviss / New product / Request / Contacts / Vacancies / Order payment / Goods receipt / Discounts